RECALL.LINE V01 RP AUTOMATION INC. 11JAN89
DESCRIPTION
The programs contained in this file are used to enable a new
feature whereby the last lines that have been typed into the
system can be recalled back onto the CRT screen, and re-entered
again as the same or different commands. When this feature is
enabled, typing <CONTROL>-B will cause the previously typed
line to appear on the screen.
PREPARATION
Load the RECALL.LINE file into memory from the diskette.
PROGRAM EXECUTION
Executing the program RECALL.LINE will modify the VAL-II system
so that every time a <CONTROL>-B is seen from the keyboard, the
last line that was typed will automatically get re-entered as
if it had been re-typed on the keyboard. This combination of
keys is accomplished by holding down the <CONTROL> key, while
at the same time, typing the 'B' key. Subsequent <CONTROL>-B
keypresses will result in lines that were previously typed. At
some point, the "save buffer" will wrap around, however, and
the data will start to repeat.
After the program is started, memory is searched for specific
data that will be changed so that this feature can be installed
into the system. If this exact data is not found, then this
is an error condition. An error message will be displayed, and
the program will be ABORT'd.
NOTES
Once this feature is installed in the system, the only way to
eliminate it is to re-load the VAL-II system.
MESSAGES
*** Correct data not found in system ***
If the data that needs to be altered is not found in the VAL-II
system, then this error message gets displayed.
A <CONTROL>-B keypress will now RECALL the last typed line
When the program is completed, then this message gets displayed
on the CRT screen.
RP Automation
Tel (800) 367-7862 (800) FOR PUMA Fax (203) 792-2154
Email info@rpautomation.com
all content copyright RP Automation 1997